HOME/APPLICATIONS
APPLICATION-LED SENSING ARCHITECTURE

Where Our Sensors Work

Application-focused sensing solutions for OEMs, equipment manufacturers and process plants.

Strong engineering companies organize sensing around applications rather than a static catalog. Explore how ACT configures pressure, level, flow, and temperature instruments for specific mechanical and hydraulic conditions.

EXPLORE BY INDUSTRIAL PROCESS

9 Targeted Application Guides

Detailed Operating Conditions & Selection Checklists
Water & Irrigation

Pressure Transmitters for Water & Pump Applications

VFD booster pumps, municipal pump houses, water distribution networks & pressure boosting skids

Pressure Transmitters for Water & Pump Applications - ACT SensorsASPT11e

Pumps starting and stopping frequently cause severe hydraulic transients (water hammer). In VFD systems, rapid response and electrical noise immunity from variable speed motor drives are mandatory.

RANGE:0–10 / 16 / 25 / 40 bar gauge
KEY RISK:Pressure spikes causing diaphragm rupture & VFD inverter electrical EMI noise
Model: ASPT11eREAD GUIDE
Compressed Air & Gas

Pressure Measurement for Compressors

Rotary screw compressors, piston compressors, centrifugal packages & air receivers

Pressure Measurement for Compressors - ACT SensorsASPT11i

Compressor discharge lines subject transmitters to continuous mechanical vibration, oily air media, discharge temperatures up to 100°C, and millions of load/unload cycles.

RANGE:0–10 / 16 / 25 bar (Air discharge), 0–6 / 10 bar (Oil circuit)
KEY RISK:Continuous pulsation vibration fatigue and oil mist fouling
Model: ASPT11iREAD GUIDE
Compressed Air & Gas

Pressure Sensors for Nitrogen Generators

PSA nitrogen generation plants, membrane separation skids & high-purity buffer vessels

Pressure Sensors for Nitrogen Generators - ACT SensorsASPT11i

Pressure Swing Adsorption (PSA) towers cycle rapidly between pressurization (typically 7–10 bar) and atmospheric regeneration every 60–120 seconds, demanding high cyclic stability.

RANGE:0–10 / 16 bar (Adsorption beds), 0–200 bar (High pressure cylinder filling)
KEY RISK:Fast cyclic pressure cycling fatigue and molecular sieve dust
Model: ASPT11iREAD GUIDE
Railways & Transportation

Pressure Transmitters for Railway Applications

Electric locomotives, EMU passenger coaches, electropneumatic braking & coach water tanks

Pressure Transmitters for Railway Applications - ACT SensorsASPT11r

Rolling stock environments experience extreme shock and vibration, wide ambient temperature fluctuations (-40°C to +85°C), and severe electrical spikes from traction motors.

RANGE:0–10 bar (Braking main reservoir), 0–2.5 mH2O (Coach water tank level)
KEY RISK:Track vibration shock (EN 61373 Category 1 Class B) and wide DC supply surges
Model: ASPT11rREAD GUIDE
Industrial Equipment

Pressure Measurement for HVAC & Chillers

Industrial screw chillers, VRF heat pumps, refrigerant loops & clean air ducts

Pressure Measurement for HVAC & Chillers - ACT SensorsASPT11v

Refrigeration lines experience phase transitions between gas and liquid, low suction pressures, and aggressive fluorinated or ammonia refrigerants with POE oils.

RANGE:-1 to 15 bar (Suction side), 0 to 35 bar (Discharge side)
KEY RISK:Hermetic seal failure leading to refrigerant leakage and condensation icing
Model: ASPT11vREAD GUIDE
Water & Irrigation

Hydrostatic Level Measurement for Irrigation

Canal drop gates, lift irrigation sumps, tube wells & agricultural balancing reservoirs

Hydrostatic Level Measurement for Irrigation - ACT SensorsASPT11s

Submerged deep underground or in sediment-heavy canal sumps where silt, algae, and lightning surges through long outdoor signal lines frequently damage sensors.

RANGE:0–5 mH2O to 0–300 mH2O (0.5 to 30 bar)
KEY RISK:Silt clogging diaphragm face and lightning transients on outdoor cable runs
Model: ASPT11sREAD GUIDE
Automotive & Mobility

Pressure Sensors for Automotive Applications

Common rail test benches, mobile hydraulic excavators, braking loops & EGR systems

Pressure Sensors for Automotive Applications - ACT SensorsASPT11v

Harsh under-the-hood and chassis environments with high thermal swings, corrosive road spray, electromagnetic transients, and 5V DC low-power ECU electronics.

RANGE:0–10 bar to 0–600 bar
KEY RISK:Automotive electrical line load dump surges and extreme vibration
Model: ASPT11vREAD GUIDE
Energy & New Applications

Pressure Measurement for Hydrogen Systems

Water electrolyzers, hydrogen storage banks, fuel cell test skids & dispensing manifolds

Pressure Measurement for Hydrogen Systems - ACT SensorsASPT11h

Hydrogen is the smallest molecule and can cause hydrogen embrittlement in certain metallic crystal lattices, alongside high risk of permeation through standard seals.

RANGE:0–35 bar (Electrolyzer stacks), 0–350 / 700 bar (Storage tanks)
KEY RISK:Hydrogen embrittlement, atomic permeation, and leak integrity
Model: ASPT11hREAD GUIDE
Water & Irrigation

Pressure Transmitters for RO Systems

Industrial reverse osmosis skids, seawater desalination, brackish water & DI polishing

Pressure Transmitters for RO Systems - ACT SensorsASPT11i

High pressure booster pumps create sudden startup spikes, while high salinity (TDS) and chlorine / brine water severely attack low-grade stainless steels.

RANGE:0–10 bar (Cartridge filter inlet/outlet), 0–70 bar (High pressure RO membrane feed)
KEY RISK:Pitting corrosion from high chlorides and membrane differential fouling
Model: ASPT11iREAD GUIDE
ACT — YOUR ENGINEERING PARTNER

Tell Us Your Application

We'll help you select the sensor. Submit your operating parameters, media compatibilities, and electrical specs to consult our application engineering team.

ACT SENSORS PVT. LTD.HQ • THANE, MAHARASHTRA
Manufacturing & Facility Address:
ACT Sensors Pvt. Ltd.
GNP Galaxy, Plot No. F4/1, F4/2, Unit No. 28, Ground Floor,
Phase 2 Kansai, Ambernath Industrial Area, Ambernath West,
Thane - 421501, Maharashtra, India
Technical Desk & Direct Sales:
+91 8879490008
Direct Engineering Inquiries:
atish@actsensor.in / shridhar@actsensor.in
Operating Hours:
Monday - Saturday: 09:00 - 18:30 IST
TRACEABLE CALIBRATION LAB

Every sensor dispatched from ACT Sensors Pvt. Ltd. undergoes rigorous testing and individualized calibration certificates traceable to national metrological standards.

● ISO 9001:2015 REGISTERED QUALITY MANAGEMENT